MP2300 Quick Reference Guide Rev1.5
LIO-01 / LIO-02
Register Allocation after Automatic Self-Configuration
Ref. Basic Module User's Manual (SIEPC88070003B) Section 6.5.
3
LIO-0x #1 LIO-0x#2 LIO-0x #1 LIO-0x#2
IW0410 IW0440 OW0411 OW0441
Input 0 IB04100 IB04400 Output 0 OB04110 OB04410
Input 1 IB04101 IB04401 Output 1 OB04111 OB04411
Input 2 IB04102 IB04402 Output 2 OB04112 OB04412
Input 3 IB04103 IB04403 Output 3 OB04113 OB04413
Input 4 IB04104 IB04404 Output 4 OB04114 OB04414
Input 5 IB04105 IB04405 Output 5 OB04115 OB04415
Input 6 IB04106 IB04406 Output 6 OB04116 OB04416
Input 7 IB04107 IB04407 Output 7 OB04117 OB04417
Input 8 IB04108 IB04408 Output 8 OB04118 OB04418
Input 9 IB04109 IB04409 Output 9 OB04119 OB04419
Input 10 IB0410A IB0440A Output 10 OB0411A OB0441A
Input 11 IB0410B IB0440B Output 11 OB0411B OB0441B
Input 12 IB0410C IB0440C Output 12 OB0411C OB0441C
Input 13 IB0410D IB0440D Output 13 OB0411D OB0441D
Input 14 IB0410E IB0440E Output 14 OB0411E OB0441E
Input 15 IB0410F IB0440F Output 15 OB0411F OB0441F
Counter
NOTE: There can be up to 2 LIO-0x modules in an MP2300 system.
The first module to be auto-configured is the left-most module.
IW0420 / OW0420
Digital Inputs
(As 16-bit word)
Digital Outputs
(As 16-bit Word)
Page 4 of 14
Page view 3
1 2 3 4 5 6 7 8 9 ... 13 14

Comments to this Manuals

No comments