3 WIRING
33
(4) Grounding Method
• Mount the braking resistor unit on a grounded metallic plate. When it
cannot be mounted on a grounded metallic plate, pull out the lead
wire from the mounting screw section to ground.
• Braking unit grounding terminal must be provided with the ground
resistance of 100Ω or less in 200V class ,or 10Ω or less in 400V class.
• Use the sizes specified in “INTERNAL CONNECTION SPECIFICA-
TIONS” for grounding cables.
3.5 INTERCONNECTION
Figs. 14 to 20 show the interconnecting diagrams of the braking unit or braking
resistor unit and VS-616G5.
Refer to Par. 3.3, “Wiring Precautions” for proper wiring in actual wiring design
and work.
Be sure to connect braking resistors or braking resistor units to the braking units.
Connect only braking resistors or Braking Resistor Units (LKEB-XXXX) to
Braking Units.
1. If using another braking resistor instead of YASKAWA braking
resistor unit, wiring sequence should shut off power to the drive
when a braking resistor Overload Relay Trip Contact (Thermal
Protector Contact) output is triggered.
2. Faulty wiring can result in fire. Make sure the interconnecting
diagrams are followed correctly.
NOTENOTE