7 Setting and Confirming CDBR Braking Unit Operation
YASKAWA ELECTRIC TOBP C720600 01C 1000-Series Option CDBR-D, LKEB- Installation Manual 55
Table 13 CDBR Enable/Disable Status (DIP Switch S1, S4)
Sink Mode (0 V Common), Internal Power Supply
Position DIP switch S1 for sinking as shown in Figure 24, when controlling the digital
SB-SC inputs by NPN transistors (0 V common/sinking mode) or contacts using the drive
internal power supply.
Figure 23
Figure 24 CDBR Braking Unit Sinking Mode using Internal Power Supply
DIP Switch S1-SINK/
SOURCE
DIP Switch S4-SB/SC
Terminals N.O./N.C.
SB-SC-Enable Input CDBR Status
SINK A Open Enabled
SINK A Close Disabled
SINK B Open Disabled
SINK B Close Enabled
SOURCE A 0 V Input Enabled
SOURCE A 24 V Input Disabled
SOURCE B 0 V Input Disabled
SOURCE B 24 V Input Enabled
+24 V
SINK-default
SOURCE
SB
SC
S4
S1
A (N.O. (default))
B
(N.C.)
TOBP_C720600_01C_3_0_E.fm 55 ページ 2013年10月7日 月曜日 午後2時20分