YASKAWA VS-626M5 Specifications Page 1

Browse online or download Specifications for Power adapters & inverters YASKAWA VS-626M5. YASKAWA VS-626M5 Specifications [en] User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 48
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Reliable and Smart
J1000
100
V CLASS, SINGLE-PHASE INPUT:
0
.
1
to
1
.
1
kW
200
V CLASS, THREE-PHASE INPUT:
0
.
1
to
5
.
5
kW
200
V CLASS, SINGLE-PHASE INPUT:
0
.
1
to
2
.
2
kW
400
V CLASS, THREE-PHASE INPUT:
0
.
2
to
5
.
5
kW
YA S K A WA
Certified for
ISO
9001
and
ISO
14001
ENVIRONMENTAL
SYSTEM
C
E
R
T
I
F
I
E
D
M
A
N
A
G
E
M
E
N
T
S
Y
S
T
E
M
JQA-EM0498
JQA-0422
QUALITY SYSTEM
C
E
R
T
I
F
I
E
D
M
A
N
A
G
E
M
E
N
T
S
Y
S
T
E
M
Compact V/f Control Drive
YASKAWA AC Drive
Page view 0
1 2 3 4 5 6 ... 47 48

Summary of Contents

Page 1 - YASKAWA AC Drive

Reliable and SmartJ1000100 V CLASS, SINGLE-PHASE INPUT: 0.1 to 1.1 kW200 V CLASS, THREE-PHASE INPUT: 0.1 to 5.5 kW200 V CLASS, SINGLE-PHASE INPUT: 0.1

Page 2 - Reliable Smart

10Easy access to the minimum-required parameters during setup.Save valuable time during setup by calling up just the parameters needed.Protect paramet

Page 3 - CONTENTS

Software Functions11Set a V/f pattern suited for the motor characteristics. Select the V/f pattern freely to gain optimal motor torque with any load c

Page 4 - Fully Equipped with User and

12Function No. Name Range DefaultInitialization ParametersA1-01Access Level Selection0,22A1-03Initialize Parameters0 to 3330 0A1-04Password 10 to 9999

Page 5 - Ensuring Stable Operation

Parameter List13Function No. Name Range DefaultMotor ParametersE2-01Motor Rated Current10 to 200% of drive rated current*2E2-02Motor Rated Slip0.00 to

Page 6 - Manufacturing

̶ALMREVDRVFOUT14Quick Setup,Easy to OperateBasic InstructionsOperator Names and FunctionsData display (5-digit)Displays frequency, parameter number, a

Page 7 - DriveWizard Plus

12345678910DRVOperation ExampleUsing the LED Operator to Run the DriveSteps Key Result/DisplayTurn the power on.Set the drive for LOCAL.The frequency

Page 8 - Application Benefi ts

CIMR-  J  A 2 A 0001 B A AHeavy DutyNormal DutyHeavy DutyNormal DutyHeavy DutyNormal DutyCIMR-JABA0001(0.8 A)CIMR-JABA0003(3.3 A)CIMR-JABA0006(6 A)CIM

Page 9 - Application Benefits

Use the table below to transition from VS mini C or VS mini J7 to the J1000 series.※The applications shown above can still use the ND rating, provided

Page 10 - Software Functions

18Parameter C6-01 sets the drive for Normal Duty or Heavy Duty performance. 200 V Class (Three-Phase/Single-Phase)ModelThree-Phase CIMR-JA2A0001 0002

Page 11

19Item Specifi cationsControl CharacteristicsControl Method V/f ControlFrequency Control Range0.01 to 400 HzFrequency Accuracy (Temperature Fluctuation

Page 12 - Parameter List

RoHScompliantSmall but ReliableReliable SmartEasy to Operateand So CompactJ1000Compact V/f Control DriveYASKAWA AC Drive2

Page 13

20Three-phase power supply 200 to 240 V 50/60 HzDC reactor (option)Thermal relay (option)Braking resistor (option)Shield ground terminalMM1MCCBMC2MCCB

Page 14 - Basic Instructions

21Terminal FunctionsMain Circuit TerminalsControl Circuit Input TerminalsTerminal Terminal Name Function (Signal Level)R/L1Main circuit power supply i

Page 15 - Setup Mode

22Enclosures Standard J1000 uses an open-chassis design (IP20). NEMA 1 kits are available to convert the standard IP20 design to a NEMA Type 1 enclosu

Page 16 - Product Lineup

23 Enclosure Panel 【NEMA Type1】Figure 1Figure 2Voltage ClassModelCIMR-JAFigureDimensions (mm)Weight(kg)CoolingNEMA 1 Kit Code No.WH DW1H1H2H3H4H5H6D1

Page 17 - Model Selection

24ModelModel NumberCIMR–JA2A0001 0002 0004 0006 0008 0010 0012 0018 0020200 VClass(Three-Phase)Motor Capacity kW0.20.40.75 1.11.52.233.75.5Rated Outp

Page 18 - Standard Specifi cations

25Cooled airCooled airMounting surfaceWall100min100minD3 minD1 D2ALMESCRESET ENTERSTOPRUNLOREDRVFOUTREVW Attachment for External HeatsinkAdditional at

Page 19 - Standard Specifications

26B1B2+2+1FuseCircuit Breaker (MCCB),Fusible disconnect Ground FaultInterruptorPower SupplyMagnetic ContactorSurge ProtectorAC ReactorInput Noise Filt

Page 20 - Standard Connection Diagram

27 Circuit Breaker, Magnetic ContactorBase device selection on motor capacity.Magnetic Contactor [Fuji Electric]Circuit Breaker[Mitsubishi Electric]Th

Page 21 - Main Circuit Terminals

28 Surge ProtectorProduct Line [Nippon Chemi-Con Corporation]Dimensions (mm)Lead250Lead910Mounting hole specifications2-3 tapped2-4 Dia.MTG holes30241

Page 22 - Dimensions

29 DC Reactor (UZDA-B for DC circuit)Base device selection on motor capacity.Connection DiagramDimensions (mm)Note: Reactor recommended for power sup

Page 23 - NEMA Type

FeaturesApplication BenefitsSoftware FunctionsParameter ListBasic InstructionsProduct LineupModel SelectionStandard SpecificationsStandard Connection

Page 24 - Drive Watts Loss Data

30 AC Reactor (UZBA-B for Input 50/60 Hz)Base device selection on motor capacity.Dimensions (mm)Connection DiagramThree-Phase 200 V Class Note: For th

Page 25 - DIN Rail Attachment

31 Zero Phase ReactorBase device selection on motor capacity.Connection DiagramDimensions (mm)Finemet Zero-Phase Reactor to Reduce Radio Noise [Hitach

Page 26

32 Capacitor-type Noise FilterDimensions (mm)Connection DiagramModel Code No.3XYG 1003C002889Rated VoltageCapacitance (3 devices each)Operating Temper

Page 27

33Input Noise Filter without CaseBase device selection on motor capacity.DimensionsConnection DiagramThree-Phase 200 V ClassSingle-Phase 200 V ClassTh

Page 28 - Surge Protector

34 Input Noise Filter with CaseBase device selection on motor capacity.Connection DiagramDimensions (mm)Three-Phase 200 V ClassNote: Connect in parall

Page 29 - B for DC circuit

35Output Noise FilterBase device selection on motor capacity.Connection DiagramThree/Single-Phase 200 V Class[NEC TOKIN Corporation]RSTJ1000Output Noi

Page 30

36 Isolator (Insulation Type DC Transmission Converter)Dimensions (mm)Connection Diagram Cable Length・4 to 20 mA: within 100 m・0 to 10 V: within 50 mP

Page 31 - Zero Phase Reactor

37Max. Motor Capacity(kW)ND/HDJ1000Braking Resistor Braking Resistor UnitMin. Connection Resistance(Ω)Three-PhaseCIMR-JA2ASingle-PhaseCIMR-JABAModelER

Page 32 - Fuse/Fuse Holder

38 Braking Resistor, Braking Resistor Unit (continued)Braking Resistor Dimensions (mm)170150200p55p0.55182441.213CDB150A30min150min150min30minMTG Scre

Page 33

39 RS-232C Interface for remote operator(Model: SI-232/J)For remote operation with the LED Operator, or for operation with DriveWizard Plus, use this

Page 34 - Input Noise Filter with Case

5002503501180800595Compact DesignEvery drive has dual rating, Normal Duty (ND) and Heavy Duty (HD). Parameter settings let the user select the rating

Page 35 - Output Noise Filter

40Peripheral Devices and Options (continued) Frequency Meter/Current MeterDimensions (mm)Note: DCF-6A is 3 V, 1 mA, 3 kΩ. For J1000 multi-function an

Page 36 - Isolator

Application Notes41適用上のご注意Application NotesSelection Installing a ReactorAn AC or DC reactor can be used for the following:・ to suppress harmonic cur

Page 37

42Application Notes (continued)General Handling Wiring CheckNever connect the power supply lines to output terminals U/T1, V/T2, or W/T3. Doing so wi

Page 38

43 Wire Gauges and Wiring DistanceMotor torque can suffer as a result of voltage loss across a long cable running between the drive and motor, especi

Page 39 - Specifi cations

Application Notes (continued)44 High Speed OperationProblems may occur with the motor bearings and dynamic balance in applications operating at over

Page 40 - Weight: approx

45Power Driven Machinery (decelerators, belts, chains, etc.)Continuous operation at low speeds wears on the lubricating material used in gear box type

Page 41 - Application Notes

46YASKAWA AC Drive SeriesName FeatureCapacity Range (kW)OutlineGeneral PurposeJ1000Compact V/f Control DriveSingle-Phase 100 V Class*10.1

Page 42

47 Global Service Network18ChicagoSan FranciscoBostonFrankfurtMumbaiSingaporeBangkokSeoulTokyoShanghaiTaipeiSydneyMelbourneNorth CarolinaMexico Cit

Page 43 - Notes on Motor Operation

J1000YASKAWA ELECTRIC CORPORATIONIn the event that the end user of this product is to be the military and said product is to be employed in any weapon

Page 44

J1000Compact V/f Control DriveYASKAWA AC DriveEnhanced BrakingStall Prevention keeps the motor running smoothly. Speed Search and Momentary Power Loss

Page 45 - Power Driven Machinery

Features3.Model Transition DriveWizard PlusTrue Reliability and Top Quality AssuranceHassle-free Maintenance Convenient Parameter ManagementYaskawa d

Page 46 - YASKAWA AC Drive Series

J1000Compact V/f Control DriveYASKAWA AC DriveFeatures4.Wide Range of Options AvailableOperate from Household Line PowerCompatible with a Single-Phase

Page 47 - Global Service Network

Fluid Applications12345678AdvantagesFunctionsApplicationsFan PumpReversePreventionMomentary Power Loss Ride-ThruMulti-StepSpeedSpeed SearchSET UPModeO

Page 48 - YA S K A WA

ND/HDSelectionOverexcitationBrakingConveyor, Transport, and Civil Applications12345678AdvantagesFunctionsApplicationsConveyorAuto ShutterAutomaticDoor

Comments to this Manuals