5.2 Alarms, Faults, and Errors
88 YASKAWA ELECTRIC TOEP C710656 08B YASKAWA Power Regenerative Unit - R1000 Instruction Manual
◆ Alarm and Error Displays
■ Faults
Table 5.2 gives an overview of possible fault codes. Conditions such as overvoltages can trip faults and alarms. It is
important to distinguish between faults and alarms to determine the proper corrective actions. When the regenerative unit
detects a fault, the ALM indicator LED lights, the fault code appears on the digital operator, and the fault contact
MA-MB-MC triggers. An alarm is present if the ALM LED blinks and the fault code on the digital operator flashes. Refer
to Minor Faults and Alarms on page 89 for a list of alarm codes.
Table 5.2 Fault Displays
Digital Operator
Display
Name Page
Digital Operator
Display
Name Page
LED LCD LED LCD
Aov
<1> Displayed as CPF00 when occurring at regenerative unit power up. When one of the faults occurs after successfully starting the regenerative
unit, the display will show CPF01. Displayed as CPF20 when occurring at regenerative unit power up. When one of the faults occurs after
successfully starting the regenerative unit, the display will show CPF21.
Power Supply Overvoltage 91 Fan Internal Circulation Fan Fault 94
AUv Power Supply Undervoltage 91 Fdv Power Supply Frequency Fault 94
bUS Option Communication Error 91 FUA AC Fuse Blowout 95
CE
MEMOBUS/Modbus
Communication Error
92 FUd DC Fuse Blowout 95
CoF Current Offset Fault 92 nSE Node Setup Error 95
,
CPF00,
CPF01
Control Circuit Error 92 oC Overcurrent 95
CPF02 A/D Conversion Error 92
to
oFA00 to
oFA43
Option Card Fault (CN5-A) 96
CPF03
Control Board Connection
Error
92
CPF06 EEPROM Memory Data Error 93
to
oFb00 to
oFb17
Option Card Fault (CN5-B) 96
CPF07
Terminal Board Connection
Error
93
CPF08
Terminal Board Connection
Error
93
to
oFC00 to
oFC55
Option Card Fault (CN5-C) 97
,
<1>
CPF11 to
CPF22
Control Circuit Error 92
oH Heatsink Overheat 98
CPF23
Control Board Connection
Error
93 oH1 Overheat 1 98
CPF24 Unit Capacity Detect Fault 93 oL2 Overload 98
to
,
to
CPF26 to
CPF35,
CPF40 to
CPF45
Control Circuit Error 92
oPr Operator Connection Fault 98
ov Overvoltage 99
PF2 Input Power Supply Fault 99
PF3 Input Phase Loss Detection 99
E5
MECHATROLINK
Watchdog Timer Error
93 SC
IGBT Short Circuit or Ground
Fault
99
EF0 Option Card External Fault 93 SrC Phase Order Fault 100
to
EF1
to
EF8
External Fault
(input terminal S1 to S8)
94
Uv1 Main Circuit Undervoltage 100
Uv2
Control Power Supply
Undervoltage
100
Err EEPROM Write Error 94 Uv3 Soft Charge Circuit Fault 101
TOEP_C710656_08B_1_0.book 88 ページ 2015年2月5日 木曜日 午前10時7分