3 Electrical Installation
12 YASKAWA ELECTRIC TOEP C710616 27A YASKAWA AC Drive - A1000 Quick Start Guide
Control Circuit Terminals
The figure below shows the control circuit terminal arrangement. The drive is equipped with screwless terminals.
There are three DIP switches and two jumpers, S1 to S5, located on the terminal board
Control Circuit Terminal Functions
S1 Terminal A2 Signal Selection
S2 RS422/485 Termination Resistor
S3
Safe Disable Input
Sink/Source/External Supply Selection
S4 Terminal A3 Analog/PTC Input Selection
S5 Terminal FM/AM Signal Selection
Type No. Terminal Name (Function) Function (Signal Level) Default Setting
Multi-Function
Digital Inputs
S1
Multi-function input 1 (Closed: Forward run,
Open: Stop)
Photocoupler
24 Vdc, 8 mA
Use the wire link between terminals SC and SN or SC and SP to select
between sinking, sourcing mode, and the power supply.
S2
Multi-function input 2 (Closed: Reverse run,
Open: Stop)
S3
Multi-function input 3 (External fault, N.O.)
S4
Multi-function input 4 (Fault reset)
S5
Multi-function input 5 (Multi-step speed
reference 1)
S6
Multi-function input 6 (Multi-step speed
reference 2)
S7
Multi-function input 7 (Jog reference)
S8
Multi-function input 8 (External baseblock)
SC
Multi-function input common –
SN Multi-function input 0 V 24 Vdc power supply for digital inputs, 150 mA max (if no digital
input option DI-A3 is used)
Never short terminals SP and SN as doing so will damage the drive.
SP Multi-function input 24 Vdc
E(G)
HC H1 H2 DM+ DM- IG R+ R- S+ S-
S1 S2 S3 S4 S5 S6 S7 S8 SN SC SP
V+ AC V- A1 A2 A3 FM AM AC MP RP AC
Use a straght-edge screwdriver
with a blade width of max 2.5 mm
and a thickness of max 0.6 mm to
release the terminals
S2
S3
S1
S4
S5
Off
On
Source Sink
External 24 Vdc
Power Supply
Analog Input PTC Input
PTC
AI
PTC
AI
AM
FM
V
I
V
I
AM
FM
FM/AM: Voltage Output FM: Current Output
AM: Voltage Output
...
Comments to this Manuals