E-7WARNING LABELMay cause burn.Disconnect all power and wait 5 min.before servicing. May causeelectric shock.Do not touch heat sink when power is ON.U
E-81 PARTSThe NS300 Module parts names are as follows:Ground wire: Connected to the terminal marked "G"on the SGDH SERVOPACK.Rotary switche
2 CHECKING ON DELIVERYE-92 CHECKING ON DELIVERY2.1 Checking ItemsWhen Σ-II Series products are delivered, check the following items:If any of the a
E-102.3 Type Designation2.4 Mounting NS300 ModuleMount an NS300 Module on a SGDH SERVOPACK in the following manner. Provide the screws for connecti
2 CHECKING ON DELIVERYE-112. Mount an NS300 Module.3. For grounding, connect a ground wire of the application module to the marked “G” onthe SERVOPAC
E-12The appearance of SERVOPACK with application module properly mounted is shown below.
3 INSTALLATIONE-133 INSTALLATIONΣ-II Series SGDH SERVOPACK is a base-mount type servo controller. Incorrect installation will cause problems. Always
E-143.3 OrientationInstall the SERVOPACK perpendicular to the wall as shown in the figure below.The SERVOPACK must be orientated as shown in the figu
3 INSTALLATIONE-15 Where mounted side by sideWhen installing SERVOPACKs side by side, provide at least 10mm (0.4in.) space between them and at least
E-164 WIRINGThis section shows a standard example for connecting Σ-II series products to peripheral devices and briefly explains how to connect each
Copyright © 2000 YASKAWA ELECTRIC CORPORATIONAll rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or tra
4 WIRINGE-174.1 DeviceNet Connection ExampleAn example of DeviceNet connection is shown below.4.2 DeviceNet Communications Connection ExampleThe fo
E-18 Configuration ElementsThe network is configured from the following elements.NodesA node is either a slave that connects to an NS300 Module or si
4 WIRINGE-19Branching to Three Drop LinesDirect Node Connection Branching from Drop LinesThere are three methods that can be used to branch from dro
E-204.3 DeviceNet Communications Connectors (CN6) The terminal layout and specifications of the CN6 connectors are shown below. Connector Specificat
4 WIRINGE-21Special DeviceNet cables can be either thick cables or thin cables. The characteristics of each type are given in the following table.The
E-22 Total Drop Line LengthThe total drop line length is a total of all drop line lengths.Length LimitsThe total drop line length must be within the
4 WIRINGE-23 Basic PrecautionsBasic precautions are as follows:• The communications power supply to the network must be 24 VDC.• The communication
E-244.5 GroundingAs shown below, connect the shield wire of the cable to the FG terminal of the communica-tions power supply and ground the shield wi
5 EDS FileE-255 EDS FileAn EDS file is required when using DeviceNet setting tool to make settings or monitor the NS300 Module. After installing the
E-26 Check Item during Test RunThe following items should be checked during test run.• Unusual vibration• Abnormal noise• Excessive temperature r
iiiINTRODUCTION Manual ContentsThis manual consists of Japanese Version and English Version.• Japanese Version: Described on pages J-1 to J-31.• E
7 INSPECTION AND MAINTENANCEE-277 INSPECTION AND MAINTENANCEThis section describes the basic inspections and maintenance. If any failure occures on
E-288 MEASURES TO SATISFY THE EMC DIRECTIVEThis section describes the measures required for the NS300 Module to conform to EMC Direc-tive (EN50081-2,
8 MEASURES TO SATISFY THE EMC DIRECTIVEE-298.4 Cable ClampFix and ground the cable sheld using a piece of conductive metal.<Example of Cable Clam
E-308.5 Wiring ExamplesThe following diagrams show the wiring example. Before wiring, turn OFF the power ON/OFF switch and post a notice of “No Cond
Revision HistoryThe revision dates and numbers of the revised manuals are given on the bottom of the back cover.Date of Publication Rev. No.Section Re
IRUMA BUSINESS CENTER (SOLUTION CENTER)480, Kamifujisawa, Iruma, Saitama 358-8555, JapanPhone 81-4-2962-5151 Fax 81-4-2962-6138http://www.yaskawa.
E-1INSTRUCTIONSΣ-II SERIES SGDHDeviceNet APPLICATION MODULESYMBOLS FOR SAFE OPERATION - - - - - - - - - - - - - - - - - - - - - - - E-4NOTES FOR SAF
E-26 OPERATION - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - E-256.1 Precautions at Test Run - - - - - - - - - - - - - - - - -
E-3This instruction manual covers Σ-II Series SGDH DeviceNet* Application Module (herein-after called NS300 Module), which is an application module to
E-4SYMBOLS FOR SAFE OPERATION In this manual, the NOTES FOR SAFE OPERATION are classified as “WARNING” or “CAUTION”. The following symbols are used.I
E-5 INSTALLATION WIRING OPERATION(Ref.No.)• Never use the equipment where it may be exposed to splashes of water, corrosive or flammable gases, o
E-6 INSPECTION AND MAINTENANCE(Ref.No.)• Be sure to turn OFF power before inspection or maintenance.Otherwise, electric shock may result.E-27• Neve