139
Specifications of Accessories Chapter 9-2
9-2-6 Digital Operator Case
3G3IV-PEZZ08386A
The Digital Operator Case (3G3IV-PEZZ08386A) is used to secure the JVOP-
140 Digital Operator. Without this Case, the Digital Operator’s connection
cable cannot be wired. Always use the JVOP-140 and the Digital Operator
Case together.
Dimensions (mm)
9-2-7 Digital Operator Connection Cable
3G3IV-PCN126/PCN326
The Digital Operator Connection Cable (3G3IV-PCN126/PCN326) is required
to connect a Digital Operator to a J7AZ Inverter.
Models and Specifications
9-2-8 DC Reactor
The DC Reactor suppresses harmonic current generated from the Inverter
and improves the power factor of the Inverter. The DC Reactor suppresses
harmonic current more effectively than the AC Reactor. Furthermore, the DC
Reactor can be used in combination with the AC Reactor.
Applicable Model
Four, 4.4-dia. mounting holes
Four depressions for
M4 bolts (Depth: 3.5)
Digital Operator Connection Cable Cable length
3G3IV-PCN126 1 m
3G3IV-PCN326 3 m
Inverter DC Reactor
Voltage
class
Max.
applicable motor
capacity (kW)
Rated current
(A)
Inductance
(mH)
200 V 0.1 to 0.75 5.4 8
1.5 to 4.0 18 3
400 V 0.2 to 0.75 3.2 28
1.5 to 2.2 5.7 11
4.0 12 6.3