Quick Start Guide
MANUAL NO. TOEP YAIQPM 02B
To properly use the product, read this manual thoroughly and retain
for easy reference, inspection, and maintenance. Ensure the end user
receives this manual.
iQpump Micro AC Drive
Compact Intelligent Pump Controller
Models:
200 V Class, Single-Phase Input: 1 to 5 HP ND
200 V Class, Three-Phase Input: 1.5 to 25 HP ND
400 V Class, Three-Phase Input: 1 to 25 HP ND
Type: CIMR-PW
Page view 0
1 2 3 4 5 6 ... 107 108

Summary of Contents

Page 1 - Quick Start Guide

Quick Start GuideMANUAL NO. TOEP YAIQPM 02BTo properly use the product, read this manual thoroughly and retain for easy reference, inspection, and m

Page 2

10YASKAWA TOEP YAIQPM 02B YASKAWA AC Drive - iQpump Micro Quick Start Guide

Page 3

No. Name DescriptionP9-09 Add Frequency LevelWhen P9-08 is set to 0, this parameter setsthe level above which the output frequencyneeds to rise for th

Page 4

No. Name DescriptionP9-32Lag FollowerDeceleration TimeSets the deceleration time when the P9-33timer is running and the drive is running asLag Drive S

Page 5

i.10 Standards ComplianceuUL Standards ComplianceThe UL/cUL mark applies to products in the United States and Canada and indicates that UL has perform

Page 6

nFactory Recommended Branch Circuit Protection for UL ComplianceYaskawa recommends installing one of the following types of branch circuit protection

Page 7

Table i.29 Control Circuit Terminal Power SupplyInput / Output Terminal Signal Power Supply SpecificationsMulti-function photocoupler output P1, P2, P

Page 8

The L1-02 parameter sets the allowed operation time before the oL1 fault occurs when the drive is running at 60 Hz and 150%of the full load amp rating

Page 9

i.11 Revision HistoryThe revision dates and the numbers of the revised manuals appear on the bottom of the back cover.MANUAL NO.Example: TOEP YAIQPM 0

Page 11

YASKAWA AMERICA, INC.2121 Norman Drive South, Waukegan, IL 60085, U.S.A.Phone: 1-800-YASKAWA (927-5292) or 1-847-887-7000 Fax: 1-847-887-7310http://

Page 12

YASKAWA TOEP YAIQPM 02B YASKAWA AC Drive - iQpump Micro Quick Start Guide11

Page 13

12YASKAWA TOEP YAIQPM 02B YASKAWA AC Drive - iQpump Micro Quick Start Guide

Page 14

YASKAWA TOEP YAIQPM 02B YASKAWA AC Drive - iQpump Micro Quick Start Guide13

Page 15

14YASKAWA TOEP YAIQPM 02B YASKAWA AC Drive - iQpump Micro Quick Start Guide

Page 16

YASKAWA TOEP YAIQPM 02B YASKAWA AC Drive - iQpump Micro Quick Start Guide15

Page 17

16YASKAWA TOEP YAIQPM 02B YASKAWA AC Drive - iQpump Micro Quick Start Guide

Page 18

YASKAWA TOEP YAIQPM 02B YASKAWA AC Drive - iQpump Micro Quick Start Guide17

Page 19

18YASKAWA TOEP YAIQPM 02B YASKAWA AC Drive - iQpump Micro Quick Start Guide

Page 20

YASKAWA TOEP YAIQPM 02B YASKAWA AC Drive - iQpump Micro Quick Start Guide19

Page 21

Copyright © 2014 YASKAWA ELECTRIC CORPORATION.No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any for

Page 22

20YASKAWA TOEP YAIQPM 02B YASKAWA AC Drive - iQpump Micro Quick Start Guide

Page 23

YASKAWA TOEP YAIQPM 02B YASKAWA AC Drive - iQpump Micro Quick Start Guide21

Page 24

22YASKAWA TOEP YAIQPM 02B YASKAWA AC Drive - iQpump Micro Quick Start Guide

Page 25

YASKAWA TOEP YAIQPM 02B YASKAWA AC Drive - iQpump Micro Quick Start Guide23

Page 26

24YASKAWA TOEP YAIQPM 02B YASKAWA AC Drive - iQpump Micro Quick Start Guide

Page 27

YASKAWA TOEP YAIQPM 02B YASKAWA AC Drive - iQpump Micro Quick Start Guide25

Page 28 - This Page Intentionally Blank

26YASKAWA TOEP YAIQPM 02B YASKAWA AC Drive - iQpump Micro Quick Start Guide

Page 29

YASKAWA TOEP YAIQPM 02B YASKAWA AC Drive - iQpump Micro Quick Start Guide27

Page 30 - WARNING

This Page Intentionally Blank28YASKAWA TOEP YAIQPM 02B YASKAWA AC Drive - iQpump Micro Quick Start Guide

Page 31

iQpump Micro Quick Start Guidei.1 PREFACE...

Page 32

uiQpump Micro AC Drive Simplex Quick Start ProcedureThis procedure is a supplement to other documentation supplied with this equipment and guides the

Page 33 - Repetitive Starting/Stopping

i.1 PrefaceYaskawa manufactures products used as components in a wide variety of industrial systems and equipment. The selection andapplication of Yas

Page 34 - Installation

WARNINGIndicates a hazardous situation, which, if not avoided, could result in death or serious injury.WARNING! may also be indicated by a bold key w

Page 35 - Motor Application Precautions

WARNINGDo not remove covers or touch circuit boards while the power is on.Failure to comply could result in death or serious injury.Make sure the pro

Page 36 - Warranty Information

NOTICEIf a fuse is blown or a Ground Fault Circuit Interrupter (GFCI) is tripped, check the wiring and the selection of theperipheral devices.Contact

Page 37 - PW 2 V 0010 F A A

Yaskawa recommends lowering the carrier frequency, particularly when audible noise is not a concern. The user can alsochoose to reduce the load, incre

Page 38 - Three-Phase 400 V Class

Transporting the DriveNOTICE: Never steam clean the drive. During transport, keep the drive from coming into contact with salts, fluorine, bromine, ph

Page 39 - Installation Environment

Submersible MotorThe rated current of a submersible motor is greater than that of a standard motor, so select the drive accordingly. Use a motorcable

Page 40 - Multiple Drive Installation

i.2 ReceivinguModel Number and Nameplate CheckPlease perform the following tasks after receiving the drive:• Inspect the drive for damage.If the drive

Page 41 - Drive Dimensions

nSingle-Phase 200 V ClassDrive Model Max. Motor Capacity kW (HP) Rated Output Current ABV0006 1.1 (1) 6.0BV0010 2.2 (3) 9.6BV0012 3.0 (3) 12.0BV0018 3

Page 42 - Standard Connection Diagram

i.3 Mechanical InstallationThis section outlines specifications, procedures, and environment for proper mechanical installation of the drive.uInstalla

Page 43 - Control circuit

4YASKAWA TOEP YAIQPM 02B YASKAWA AC Drive - iQpump Micro Quick Start Guide

Page 44

nSingle Drive InstallationFigure i.6 shows the required installation spacing to maintain sufficient space for airflow and wiring for IP20/NEMA Type1 a

Page 45 - (2-Wire)

uDrive DimensionsNOTICERefer to the iQpump Micro User Manual TOEP YAIQPM 03 for IP20/NEMA Type 1 and IP66/NEMA Type 4X dimensions.The iQpump Micro Use

Page 46

i.4 Electrical InstallationuStandard Connection DiagramConnect the drive and peripheral devices as shown in Figure i.9. It is possible to run the driv

Page 47

+- 1 MCCBMC2 MCCBr1s1t1<3>R/L1S/L2T/L3For single-phase200 V power supplyuse R/L1 and S/L2. Three phasepower supplyfor 200 V / 400 VTermi

Page 48

<1> Remove the jumper when installing an optional DC link choke.<2> The MC on the input side of the main circuit should open when the ther

Page 49 - Wire Range

uTransducer Connection Diagrams Signal Wire (white) 24 V PSU to Drive A224VACFE24V Power Supply ShieldSIGFEFunctional Earth Cable (Blue)J

Page 50 - Output Terminals

i.5 Main Circuit WiringThis section describes the functions, specifications, and procedures required to safely and properly wire the main circuit ofth

Page 51 - Terminal Configuration

DriveModelTerminalRecomm.GaugeAWG, kcmilWire RangeAWG, kcmilScrewSizeTighteningTorqueN•m (lb.in.)BV0012R/L1, S/L2, T/L3 10 14 to 10M42.3 to 2.5(20.4 t

Page 52

DriveModelTerminalRecomm.GaugeAWG, kcmilWire RangeAWG, kcmilScrewSizeTighteningTorqueN•m (lb.in.)2V0056R/L1, S/L2, T/L3 4 6 to 4M65.4 to 6.0(47.8 to 5

Page 53

DriveModelTerminalRecomm.GaugeAWG, kcmilWire RangeAWG, kcmilScrewSizeTighteningTorqueN•m (lb.in.)4V0031R/L1, S/L2, T/L3 8 10 to 6M53.6 to 4.0(31.8 to

Page 54 - DIP Switch S3

YASKAWA TOEP YAIQPM 02B YASKAWA AC Drive - iQpump Micro Quick Start Guide5

Page 55

Figure i.13 Multiple Drive WiringuControl Circuit Terminal Block FunctionsDrive parameters determine which functions apply to the multi-function digit

Page 56 - Wiring Checklist

Type No. Terminal Name (Function) Function (Signal Level) Default SettingMulti-FunctionPhotocoupler OutputP1 Photocoupler output 1 (During run)Photoco

Page 57

nWire Size and Torque SpecificationsSelect appropriate wire type and size from Table i.10. For simpler and more reliable wiring, crimp ferrules to the

Page 58 - AUTO OFF

NOTICE: Do not tighten screws beyond the specified tightening torque. Failure to comply may damage the terminal block.NOTICE: Use shielded twisted-pai

Page 59 - DRIVE MODE

uSinking/Sourcing Mode SwitchSet the DIP switch S3 on the front of the drive to switch the digital input terminal logic between sinking mode and sourc

Page 60

nTransistor Input Signal Using +24 V Common/Source ModeWhen controlling digital inputs by PNP transistors (+24 V common/sourcing mode), set the DIP sw

Page 61 - <2>

V IFigure i.23 DIP Switch S1Table i.14 DIP Switch S1 SettingsSetting Value DescriptionV (eft position) Voltage input (0 to 10 V)I (right position) Cur

Page 62 - YYYY/MM/DD HH:MM

No. Item Page13Set up overload protection circuits when running multiple motors from a single drive.M1OL1OL2OLnMC1MC2MCnM2MnDriveMC1 - MCn OL 1 - OLn

Page 63 - Clock Not Set

i.6 Start-Up Programming and OperationuKeys, Displays, and LEDs on the Standard LED Operator5111121381514161023AUTO OFFHAND4 679Table i.16 Keys and Di

Page 64 - No Setting (Default)

No. Display Name Function16 – Communication PortPort used for USB Copy Unit, LCD Operator Keypad, and for connecting to a PC.NOTICE: Use only specifie

Page 65 - Initial Display <5>

6YASKAWA TOEP YAIQPM 02B YASKAWA AC Drive - iQpump Micro Quick Start Guide

Page 66 - 3-Wire Control

uKeys and Displays on the Optional HOA KeypadF2F1ESCM MAUTO OFFENTERRESETALMDIGITAL OPERATOR JVOP-183HAND121198123104 5 6 7Figure i.25 Keys and Displa

Page 67

uLCD DisplayFigure i.26 LCD DisplayTable i.17 Display and ContentsNo. Name Display Content1 Operation Mode MenusMODE Displayed when in Mode Selection.

Page 68 - DIP switch S1

No. Name Display Content8 FWD/REVFWD Indicates forward motor operation.REV Indicates reverse motor operation.9Function Key 1(F1)<-MONITOR->Press

Page 69 - Setting 4: Pulse Train Input

Changing Settings• Changing YYYY/MM/DD HH:MM: Pressing the up arrow key will increase the number selected by the cursor from 0 to9. Pressing the down

Page 70

Procedure Display3 Press the ENTER key to enter select the parameter setting mode.- PRMSET - PRGALMInitializationA1-00 = 0Select LanguageFWDALMHOMED

Page 71 - Max. output frequency (E1-04)

uMenu Structure for HOA Keypad- MODE -U5-99= 0.0PSIU1-02= 0.00HzU1-91= 0.0PSIDRVAuto SetpointRdy<4>- MODE -U1-01= 0.00HzU1-02= 0.00HzU1-91= 0.

Page 72

uDetailed Parameter DescriptionsnA1-03: Initialize ParametersResets parameters to default values or performs an Application Preset for fan or pump app

Page 73

Setting 6008: Pressure ControlApplication Preset for Pressure Control applications.Setting 6009: Pump Down LevelApplication Preset for Pump Down Level

Page 74

Figure i.30 Setting the Frequency Reference by Voltage Input• Using Control Circuit Terminal A2 (0 to 10 Vdc voltage input)Use the same connection as

Page 75

Figure i.32 Switching between Analog Reference 1 and 2Setting 2: MEMOBUS/Modbus CommunicationsThis setting requires entering the frequency reference v

Page 76 - P1-01: Pump Mode

YASKAWA TOEP YAIQPM 02B YASKAWA AC Drive - iQpump Micro Quick Start Guide7

Page 77 - P1-02: System Units

Pulse Train Input SpecificationsResponse Frequency 0.5 to 32 kHzDuty Cycle 30 to 70%High Level Voltage 3.5 to 13.2 VLow Level Voltage 0.0 to 0.8 VInpu

Page 78 - Fault Detection

No. Parameter Name Setting Range Defaultb1-03 Stopping Method Selection 0 to 3 1Setting 0: Ramp to StopWhen the Run command is removed, the drive will

Page 79 - <1>

Output frequency when Stop command was entered100%(Maximum output frequency)10%DC Injection braking timeb2-04×10b2-04Figure i.36 DC Injection Braking

Page 80

Setting 1: EnabledThis setting performs Speed Search when the Run command is entered. The drive begins running the motor after Speed Searchis complete

Page 81 - Alarm Detection

nE2-01: Motor Rated CurrentProvides motor control, protects the motor, and calculates torque limits. Set E2-01 to the full load amps (FLA) stamped ont

Page 82

Table i.22 Stopping Method for External FaultSettingTerminal Status <1>Detection Conditions <2>Stopping MethodN.O. N.C.AlwaysDetectedDetec

Page 83

Table i.23 Multi Setpoints 1 and 2Multi Setpoint 1(H1-0o = 8D)Multi Setpoint 2(H1-0o = 8E)Setpoint SourceOpen OpenFrequency Ref (dependent on b1-01),

Page 84 - Operator Programming Errors

• Over-cycle Protection: Active when the drive is the only drive running on the network.• Pre-charge: Active only on the first drive to run in the net

Page 85

i.7 TroubleshootingNOTICERefer to the iQpump Micro User Manual TOEP YAIQPM 03 for complete information on Troubleshooting causes andsolutions.The iQpu

Page 86 - Fault Reset Methods

Digital OperatorDisplayFault NameCPF22A/D Conversion FaultA/D conversion error.CPF23 PWM Feedback FaultCPF24<1>Drive Unit Signal FaultThe drive

Page 87 - <4>

8YASKAWA TOEP YAIQPM 02B YASKAWA AC Drive - iQpump Micro Quick Start Guide

Page 88 - <5>

Digital OperatorDisplayFault NameLWL(LOH20)Low Water LevelThe “Low Water Level” digital input is active (H1-0o = 8F).MSLNet Master Lost(NSL)Net Master

Page 89 - Single-Phase Derating

Digital OperatorDisplayFault NamerrDynamic Braking TransistorThe built-in dynamic braking transistor failed.SC IGBT Short Circuit or Ground FaultSErTo

Page 90

Digital OperatorDisplayAlarm NamebUSOption Communication Error• The connection was lost after establishing initial communication.• Only detected when

Page 91 - Adjustment

Digital OperatorDisplayAlarm NameHigh Feedback High FBSensed(HIFB)High Feedback Level AlarmThe feedback signal is too high.LOPLoss of PrimeThe pump ha

Page 92

Digital OperatorDisplayAlarm NameR-DNE-So(Rdd)Remote Drive DisableSEMEMOBUS/Modbus Communication Test Mode ErrorNote: This alarm will not trigger a mu

Page 93

uDigital Operator Display MessagesTable i.24 lists messages and errors that may appear during normal pump operation.These messages do not trigger mult

Page 94

uFault Reset MethodsAfter the Fault Occurs ProcedureFix the cause of the fault, restart thedrive, and reset the faultPress on the digital operator.Pr

Page 95

i.8 Drive SpecificationsNote: For optimum performance life of the drive, install the drive in an environment that meets the required specifications.It

Page 96

Item SpecificationProtectionFunctionsHeatsink Overheat Protection Protected by thermistorBraking Resistor Overheat Protection Overheat input signal fo

Page 97

uSingle-Phase DeratingiQpump Micro drives are compatible for use with both three-phase and single-phase input power supplies. The drive outputto the m

Page 98 - Note: Feedback depends on PID

YASKAWA TOEP YAIQPM 02B YASKAWA AC Drive - iQpump Micro Quick Start Guide9

Page 99

i.9 Parameter TableThis parameter table shows the most important parameters. Default settings are in bold type. Refer to the User Manual formore detai

Page 100

No. Name Descriptionb3-10Speed SearchDetectionCompensation GainSets the gain which is applied to the speeddetected by Speed Estimation Speed Searchbef

Page 101

No. Name DescriptionC3-03Slip CompensationLimitSets an upper limit for the slipcompensation function as a percentage ofmotor rated slip for motor 1 (E

Page 102 - UL Standards Compliance

No. Name DescriptionE2-04 Number of Motor PolesSets the number of motor poles.Automatically set during Auto-Tuning.E2-05Motor Line-to-LineResistanceSe

Page 103

No. Name DescriptionH6-01Pulse Train InputTerminal RP FunctionSelection0: Frequency reference1: PID feedback value2: PID setpoint valueH6-02Pulse Trai

Page 104 - E2-01: Motor Rated Current

No. Name DescriptionL3-20DC Bus VoltageAdjustment GainSets the proportional gain for KEB Ride-Thru, Stall Prevention, and overvoltagesuppression.L3-21

Page 105

No. Name DescriptionL8-07Output Phase LossProtection Selection0: Disabled1: Enabled (triggered by a single phaseloss)2: Enabled (triggered when two ph

Page 106

No. Name Descriptiono2-05Frequency ReferenceSetting MethodSelection0: ENTER key must be pressed to entera frequency reference.1: ENTER key is not requ

Page 107

No. Name DescriptionP1-18Prime Loss DetectionMethod0: Current (A)1: Power (kW)2: Torque (%)P1-19 Prime Loss LevelDetects loss of prime in the pump whe

Page 108

No. Name DescriptionP4-13Thrust BearingDeceleration TimeSets the amount of time it takes to bring thedrive from the Thrust Frequency set inP4-12 to st