Date: 12/02/04, Rev: 04-12 Page 1 of 6 TM.V7SW.030
CUSTOM SOFTWARE DESCRIPTION
V7 Low HP
Decel Positioning Software
CIMR-V7AMXXXXX-030
(20P1 ~ 23P7, 40P2 ~ 43P7)
Software Number: VSP018044 Base Version: VSP017902
Product: V7 Part Number: CIMR-V7AMXXXX-030
Original Release Date: 5/24/00 Author: Ty Phillips Beta Version
Overview: For rotary indexing application. Modifies the decel time based on frequency reference.
Revision History:
VSP018040 - Original Version.
VSP018041 - Corrected formula for alternate decel calculation 8/17/00.
VSP018043 - Added compensation function (P-05, P-06) 11/20/03.
VSP018044 - Added Ink Dip Function 8/5/04.
A
Wor
l
d of Automation Solutions
TM
Page view 0
1 2 3 4 5 6

Summary of Contents

Page 1 - Decel Positioning Software

Date: 12/02/04, Rev: 04-12 Page 1 of 6 TM.V7SW.030 CUSTOM SOFTWARE DESCRIPTION V7 Low HP Decel Positioning Software CIMR-V7AMXXXXX-030 (2

Page 2

Date: 12/02/04, Rev: 04-12 Page 2 of 6 TM.V7SW.030 1. Background This software is designed for use on a rotary silkscreen-printing machine. The

Page 3

Date: 12/02/04, Rev: 04-12 Page 3 of 6 TM.V7SW.030 2. Overview This software is intended for simple positioning applications using limit switche

Page 4

Date: 12/02/04, Rev: 04-12 Page 4 of 6 TM.V7SW.030 3.2 Multi-function input settings (n050 ~ n056) Setting Description 100 Position Speed Select

Page 5

Date: 12/02/04, Rev: 04-12 Page 5 of 6 TM.V7SW.030 5. Timing Diagrams Output FrequencyTimeFrequency ReferenceDecel Time =tdecel x (Fmax / Fout)2 x

Page 6

Date: 12/02/04, Rev: 04-12 Page 6 of 6 TM.V7SW.030 Output FrequencyTimeInk Dip decel time:If P-01 = 1: selected decel time (n020 or n022)If P-01 = 2