FREQUENCY
ACCEL TIME
(n16)
DECEL TIME
(n17)
MAX. OUTPUT
FREQUENCY
RUN
COMMAND
ON
TIME
16
VS mini J7
PROGRAMMING FEATURES
Programming features of VS mini J7 are explained
according to the following items.
Accel time : Sets the time needed for the motor to
accelerate to the maximum output
frequency from the stopped status.
Decel time : Sets the time needed for the motor to
stop from the maximum output frequency.
Item Setting Function
Ref.
Page
Accel/decel time setting
V/f pattern setting
Motor rotation direction setting
LOCAL (operator) /REMOTE
(control circuit terminal) selection
Motor rated current setting
Operation mode selection
Constant set-up
Reverse run prohibit
Multi-step speed selection
Adjusting frequency setting signal
Operation at low speed
Adjusting frequency upper and
lower limits
Using two accel/decel times
Automatic restart after momentary
power loss
Soft-start characteristics
Torque detection
Continuing operation by automatic
fault reset
Frequency detection
Avoiding resonance
Operating coasting motor without trip
Holding accel/decel temporarily
Using frequency meter or ammeter
Reducing motor noise or leakage current
Operator stop key selection
Selecting stopping method
Applying DC injection braking
23
23
23
18
18
19
19
19
19
20
20
20
20
21
21
21
22
22
22
Items Should
be Verified
Before
Operation
Setting
Operating
Condition
Selecting
Stopping
Method
Using input signals
Using output signals
23
25
Building
Interface
Circuits with
External
Devices
Adjusting torque according to application
Preventing motor from stalling
(current limit)
25
26
Adjusting
Motor Torque
Slip compensation 27
Decreasing
Motor Speed
Fluctuation
Motor overload detection 27
Protecting
Motor
16
16
17
17
17
17
17
n11=60Hz
BASE
POINT
CONSTANT
TORQUE
CONSTANT OUTPUT
OR VARIABLE OUTPUT
n10
=200V
n09=90Hz
Sets the V/f pattern which matches the motor characteristics.
When operating at 50/60Hz or more frequency, change only
the max. output frequency (n09) as follows.
Items Should be Verified Before Operation
The set value displayed in is factory setting.
Accel/decel time setting
Accel time 1, 2
Decel time 1, 2
N19N17
N18N16
V/f pattern setting
Max. output frequency
Max. voltage
Max. voltage output frequency
N11
N10
N09
Page view 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 43 44

Comments to this Manuals