2.24 REMOTE/LOCAL AND REFERENCE SELECTION Continued
Mode 3 (An-01, Manual, An-03 thru An-09) uses An-01, Manual and An-03 thru
An-09.
The input commands at terminals 5 thru 8 are
binary coded to select the appropriate reference
command, where An-01 is selected by binary zero
and An-09 (Jog) is selected by binary 8. For
example, if the value in An-04 is the desired
frequency reference, enter 0011 at terminals 5
thru 8. As a standard, the right-most bit and
terminal 5 are the LSB.
Sn-04 = local operation.
Sn-15 = frequency reference select 1 at
terminal 5 (Auto/Manual).
Sn-16 = frequency reference select 2 at
terminal 6.
Sn 17 = frequency reference select 3 at
terminal 7.
Sn-18 = JOG reference select at terminal 8.
Sn-19 = manual reference at terminal 16.
2-WIRE CONTROL
3-WIRE CONTROL
Sn-04 = X X X
1
Sn-04 = X X X
1
Sn-15 =
03
Sn-15 =
00
Sn-16 =
04
Sn-16 =
03
Sn-17 =
05
Sn-17 =
04
Sn-18 =
06
Sn-18 =
06
Sn-19 =
00
Sn-19 =
00
GPD 503
5
(Sn-15)
6
(Sn-16)
7
(Sn-17)
8
(Sn-18)
F000.0
Freq.
External Terminal
Ref.
8765
An-01 0 0 0
Manual 0 0 1
(Multi-func.)
An-03 0 1 0
An-04 0 1 1
An-09 1 X X
Freq.
External Terminal
Ref.
8765
Freq.
External Terminal
Ref.
8765
An-01 0000
Manual 0001
(Multi-func.)
An-03 0010
An-04 0011
An-05 0100
An-06 0101
An-07 0110
An-08 0111
An-09 1 X X X
Freq.
External Terminal
Ref.
8765
1 = Closed; 0 = Open;
X = No effect; = FWD/REV