Varispeed-656DC5System Regen Convertor (VS-656DC5)Model: CIMR-D5A400V Class 200~800kW (300~1200kVA)600V Class 300~1200kW (400~1600kVA)Enclosure Instal
VS-656DC5 Enclosure Installation Manual8 - 232. TransportThere are two methods for transporting the enclosure, by crane or by pushing on a loading car
VS-656DC5 Enclosure Installation Manual9 - 232.3 Pushing on A Gas-Assisted Loading CartWhen transporting using a gas-assisted loading cart, take care
VS-656DC5 Enclosure Installation Manual10 - 233. InstallationPerform the installation of the enclosure in accordance with the following items.3.1 Prep
VS-656DC5 Enclosure Installation Manual11 - 23Linking Apertureφ 14 × 4Figure 3.1 Row Linking of EnclosureM10×90 boltlock washerM10×60 boltlock washerT
VS-656DC5 Enclosure Installation Manual12 - 233.4 Tightening of Base BoltsTighten the base bolts (4 locations) to the enclosure after finishing the wo
VS-656DC5 Enclosure Installation Manual13 - 234. WiringConnect the cabling to the enclosure while referencing the wiring connection diagram pro-vided
VS-656DC5 Enclosure Installation Manual14 - 23 400V-Class/400kW, 600V-Class/800kW575V-Class/600kW, 900V-Class/1200kWFigure 4.2 is an example of a
VS-656DC5 Enclosure Installation Manual15 - 234.2 Control Circuit Wiring4.2.1 The Control Circuit Terminal Block and The General Terminal BlockMaintai
VS-656DC5 Enclosure Installation Manual16 - 235. Grounding5.1 Connecting the Grounding BusWhen the enclosure in mounted in series with an I/O terminal
VS-656DC5 Enclosure Installation Manual17 - 236. Maintenance/InspectionAppropriate maintenance management is necessary in order to assure reliable ope
Table of ContentsSafety Notes ...3
VS-656DC5 Enclosure Installation Manual18 - 236.2 Maintenance InspectionPerform inspection according to the schedule shown in Table 6.1. Table 6.1: M
VS-656DC5 Enclosure Installation Manual19 - 236.3 Module Installation/RemovalThe converter module is heavy. Three persons should perform the installat
VS-656DC5 Enclosure Installation Manual20 - 23*: Does not include cart dimensions.6.3.2 Module InstallationTo install the module, perform the removal
VS-656DC5 Enclosure Installation Manual21 - 236.4 Enclosure Exchange Fan UnitA fan unit for releasing hot air within the enclosure is installed in the
VS-656DC5 Enclosure Installation Manual22 - 236.5 Module Disposal• Prior to disposing of the module, drill a hole in the heat pipe mounted within the
VS-656DC5 Enclosure Installation Manual23 - 237. Spare Parts7.1 Enclosure(×1)~(×4) refers to the number of spare parts per set.Voltage (V)Capacity (kW
YASKAWA ELECTRIC AMERICA, INC.Chicago-Corporate Headquarters 2121 Norman Drive South, Waukegan, IL 60085, U.S.A.Phone: (847) 887-7000 Fax: (847)
VS-656DC5 Enclosure Installation Manual1 - 23YASKAWA ELECTRIC CORPORATIONSafety SymbolsThis manual uses the following symbols according to safety-rela
VS-656DC5 Enclosure Installation Manual2 - 23
VS-656DC5 Enclosure Installation Manual3 - 23Safety NotesBe sure prior to installation, running, maintenance, and inspection, to thoroughly read this
VS-656DC5 Enclosure Installation Manual4 - 23 Maintenance/Testing Module Installation/RemovalSee Page• Do not touch the terminals on the enclo
VS-656DC5 Enclosure Installation Manual5 - 23 General Cautionary Items• The figures and photographs in this manual are representative examples. Th
VS-656DC5 Enclosure Installation Manual6 - 231. Product ChecksNext, we will describe the procedure for checking the product upon arrival.1.1 Checks Up
VS-656DC5 Enclosure Installation Manual7 - 231.2.2 Storage MethodStore the enclosure by the following method:• Do not place the enclosure directly on
Comments to this Manuals