5. Operating the Inverter
41
Fault History Display Method
Fault description is displayed when U09 is selected.
(Example)
: Fault description
“---” is displayed if there is no fault.
(Refer to page 97 for details.)
Clearing the Fault History
Set constant n01 to 6 to clear the fault history. Set data returns to its ini-
tial value after 6 is set.
Note: Initializing the constants (n01=8, 9) also clears the fault history.
Setting and Referencing Constants
The following diagram shows how to select and change constants.
Simple Data Setting
Digital setting (refer to 5. Operating the Inverter) and potentiometer
setting are both possible for simple acceleration/deceleration operation
of the VS mini.
Frequency reference by potentiometer signal is set with initial setting
(n03=0).
Factory setting of the model with operator (without potentiometer) is set
by Digital Operator (n03=1).
REMOTE/LOCAL
selection
Constant
No./
data
n02
RUN command
selection
Initial setting: 0
operator reference
Set to 1
Control circuit
terminal reference
(flashing at changing)
Data set
After
1 s
Return to
constant No.
display
Setting n02 (RUN command selection)
PRGM
DSPL
DSPL
ENTER ENTER
FREF
PRGM
PRGM
PRGM
LO/RE
PRGM
PRGM