Page view 55
5.8 Utility Functions
E-55
English
5.8 Utility Functions
Utility Function List
Alarm History Display (Fn000)
This function displays the last ten alarms that have occurred in the SERVOPACK.
The latest ten alarm numbers and time stamps* can be checked.
* Time Stamps
A function that measures the ON times of the control power supply and main circuit power supply in 100-ms units
and displays the total operating time when an alarm occurs. The time stamp operates around the clock for approxi-
mately 13 years.
<Example of Time Stamps>
If 36000 is displayed,
3600000 [ms] = 3600 [s] = 60 [min] = 1 [h]
Therefore, the total number of operating hours is 1 hour.
Preparation
There are no tasks that must be performed before displaying the alarm history.
Fn No. Function Remarks
Fn000 Alarm History Display
Fn002 JOG Operation
Fn003 Origin Search
Fn006 Clearing Alarm History
Fn010 Write Prohibited Setting Cannot to be changed.
Fn012 Software Version Display