NOTE
Simple Data Setting
Potentiometer setting (Refer to 5. OPERATING THE INVERTER) and
digital setting are both available for simple accel/decel operation of the VS
mini.
Frequency reference by potentiometer signal is set with initial setting
(n03=0).
Factory setting of the model with operator (without potentiometer) is set by
digital operator (n03=1).
Following is an example in which the function LEDs are used to set
frequency reference, acceleration time, deceleration time, and motor
direction.
Operation Steps
1. Turn ON the power supply.
7. Press to stop.
STOP
Operator
Display
LED
Display
Status Indicator
LED
2. Set constant n03 to 1.
3. Set the following constants.
4. Select forward or reverse run by
pressing q or w key.
5.
Set the reference by pressing qor w
key.
6. Press .
15.0
5.0
0.0
1
60.0
0.0 to 60.0
FREF
PRGM
FOUT
PRGM
n16 : 15.0 (acceleration time)
n17 : 5.0 (deceleration time)
Examine the application.
(Never select REV when
reverse run is prohibited.)
RUN
FOUT
FREF
F/R
60.0 to 0.0
(Forward)
(Reverse)
or
Status indicator lamp : BLINKING (Long Blinking) : BLINKING : OFF
RUN ALARM
RUN ALARM
RUN ALARM
RUN ALARM
RUN ALARM
RUN ALARM
RUN ALARM
Page view 34