By inputting a jog command and then a forward (reverse) run command,
operation is enabled at the jog frequency set in n29. When multi-step speed
references 1, 2, 3 or 4 are input simultaneously with the jog command, the
jog command has priority.
ON
ONON ON ON
ONON
ON
TIME
(n28) 60.0 Hz
(n27) 55.0 Hz
(n26) 50.0 Hz
(n25) 45.0 Hz
(n24) 40.0 Hz
(n23) 35.0 Hz
(n22) 30.0 Hz
(n21) 25.0 Hz
FREQUENCY
REFERENCE
FWD (REV) RUN/STOP
MULTI-STEP SPEED REF. 1
(TERMINAL S3)
MULTI-STEP SPEED REF. 2
(TERMINAL S4)
MULTI-STEP SPEED REF. 3
(TERMINAL S5)
Operating at low speed
Name
Jog frequency
Jog command
Constant No.
n29
n36 to n39
Setting
Factory setting : 6.0Hz
Set to 10 for any constant.