Parameters A - 28
H3-06
Terminal A3 Gain Setting
Terminal A3 Gain
Sets the output level when 10V is input.
0.0 to
1000.0
100.0% A A A A
H3-07
Terminal A3 Bias Setting
Terminal A3 Bias
Sets the frequency reference when 0V is input.
–100.0 to
+100.0
0.0% A A A A
H3-08
Terminal A2 Signal Level
Selection
Term A2 Signal
Selects the signal level of terminal A2.
0: 0 to 10Vdc (switch S1-2 must be in the OFF position).
1: -10 to +10Vdc (switch S1-2 must be in the OFF position).
2: 4 to 20mA (switch S1-2 must be in the ON position)
0 to 2 2 A A A A
H3-09
Terminal A2 Function
Selection
Terminal A2 Sel
Selects the function of terminal A2.
Same choices as Terminal A3 Function Selection (H3-05).
0 to 1F 0 A A A A
H3-10
Terminal A2 Gain Setting
Terminal A2 Gain
Sets the output level when 10V is input.
0.0 to
1000.0
100.0% A A A A
H3-11
Terminal A2 Bias Setting
Terminal A2 Bias
Sets the output level when 0V is input.
–100.0 to
+100.0
0.0% A A A A
H3-12
Analog Input Filter Time
Constant
Filter Avg Time
This parameter adjusts the filter on all 3 analog inputs. Increase to
add stability, decrease to improve response.
0.00 to
2.00
0.03sec A A A A
Analog Outputs
H4-01
Terminal FM Monitor
Selection
Terminal FM Sel
Selects which monitor will be output on terminals FM and FC.
1: Frequency Reference
100% = Maximum output frequency E1-04.
2: Output Frequency
100% = Maximum output frequency E1-04.
3: Output Current
100% = Drive rated current.
5: Motor Speed
100% = Maximum output frequency E1-04.
6: Output Voltage
100% = 200/400Vac depending on Drive voltage rating.
7: DC Bus Voltage
100% = 400/800Vdc depending on Drive voltage rating.
8: Output kWatts
100% = Drive rated power.
9: Torque Reference
100% = Motor rated torque.
15:Terminal A1 Input Level
100% = 10Vdc
16:Terminal A2 Input Level
100% = 10Vdc or 20mA
17:Terminal A3 Input Level
100% = 10Vdc
18:Motor Secondary Current
100% = Motor rated secondary current.
19:Motor Excitation Current
100% = Motor rated magnetizing current.
20:SFS Output
100% = Maximum output frequency E1-04.
21:ASR Input
100% = Maximum output frequency E1-04.
22:ASR Output
100% = Maximum output frequency E1-04.
24:PID Feedback
100% = Maximum output frequency E1-04.
26:Output Voltage Reference Vq
100% = E1-05, default 240V or 480V.
27:Output Voltage Reference Vd
100% = E1-05, default 240V or 480V.
31:Not Used
32:ACR q Output (100% = Motor rated secondary current)
33:ACR d Output (100% = Motor rated magnetizing current)
36:PID Input
100% = Maximum output frequency E1-04.
37:PID Output
100% = Maximum output frequency E1-04.
38:PID Setpoint
100% = Maximum output frequency E1-04.
44:ASR Output Without Filter
45:Feedforward Control Output
100% = Motor rated secondary current.
1 to 45 2 A A A A
Denotes that parameter can be changed when the Drive is running.
Table A.1 F7 Parameter List (Continued)
Parameter
No.
Parameter Name
Digital Operator Display
Description
Setting
Range
Factory
Setting
Control Method
V/F
V/F
w/PG
Open
Loop
Vector
Flux
Vector
Page view 192