Yaskawa Matrix Converter User Manual Page 132

  • Download
  • Add to my manuals
  • Print
  • Page
    / 398
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 131
5-32
F5: Digital Output Cards (DO-02C and DO-08)
Parameter
Number
Name
Description
Setting
Range
Default
Change
during
Run
Control
Methods
MEMO-
BUS
Register
Page
Display
V/f
Open
Loop
Vector
Flux
Vector
F4-08
AO-12 Channel 2
Signal Level
0: 0 to 10 VDC
1: -10 to +10 VDC
0 or 1 0 No A A A 398H 6-80
AO Opt Level
Ch2
Parameter
Number
Name
Description
Setting
Range
Default
Change
during
Run
Control
Methods
MEMO-
BUS
Register
Page
Display
V/f
Open
Loop
Vector
Flux
Vector
F5-01
DO-02/DO-08
Channel 1 Output
Selection
Sets the digital output function number
for channel 1. See the H2 parameter
group for possible selections.
Enabled when digital output card DO-02
or DO-08 is used.
0 to 37 0 No A A A 399H 6-138
DO Ch1 Select
F5-02
DO-02/DO-08
Channel 2 Output
Selection
Sets the digital output function number
for channel 2. See the H2 parameter
group for possible selections.
Enabled when digital output card DO-02
or DO-08 is used.
0 to 37 1 No A A A 39AH 6-138
DO Ch2 Select
F5-03
DO-08 Channel 3
Output Selection
Sets the digital output function number
for channel 3. See the H2 parameter
group for possible selections.
Enabled when digital output card DO-02
or DO-08 is used.
0 to 37 2 No A A A 39BH 6-138
DO Ch3 Select
F5-04
DO-08 Channel 4
Output Selection
Sets the digital output function number
for channel 4. See the H2 parameter
group for possible selections.
Enabled when digital output card DO-02
or DO-08 is used.
0 to 37 4 No A A A 39CH 6-138
DO Ch4 Select
F5-05
DO-08 Channel 5
Output Selection
Sets the digital output function number
for channel 5. See the H2 parameter
group for possible selections.
Enabled when digital output card DO-02
or DO-08 is used.
0 to 37 6 No A A A 39DH 6-139
DO Ch5 Select
F5-06
DO-08 Channel 6
Output Selection
Sets the digital output function number
for channel 6. See the H2 parameter
group for possible selections.
Enabled when digital output card DO-02
or DO-08 is used.
0 to 37 37 No A A A 39EH 6-139
DO Ch6 Select
F5-07
DO-08 Channel 7
Output Selection
Sets the digital output function number
for channel 7. See the H2 parameter
group for possible selections.
Enabled when digital output card DO-02
or DO-08 is used.
0 to 37 0F No A A A 39FH 6-139
DO Ch7 Select
F5-08
DO-08 Channel 8
Output Selection
Sets the digital output function number
for channel 8. See the H2 parameter
group for possible selections.
Enabled when digital output card DO-02
or DO-08 is used.
0 to 37 0F No A A A 3A0H 6-139
DO Ch8 Select
Page view 131