Parameters
10-23
10
Table 10.2 Parameters (Continued)
L8-12 Ambient Temperature Setting 45
L8-15
OL2 Characteristic Selection at
Low Speeds
1
L8-42 Factory Adjustment 1 2
n1-01
Hunting Prevention Selection 1
n1-02 Hunting Prevention Gain Setting 1.00
n1-03 Hunting Prevention Time Constant 10
n2-01
Speed Feedback Detection Con-
trol (AFR) Gain
1.00
n2-02
Speed Feedback Detection Con-
trol (AFR) Time Constant
100
n2-03
Speed Feedback Detection Con-
trol (AFR) Time Constant 2
750
n5-01 Feed Forward Control Selection 0
n5-02 Motor Acceleration Time
0.168
*3
n5-03 Feed Forward Control Ratio Gain 1.0
o1-01 User Monitor Selection 6
o1-02
User Monitor Selection After
Power-Up
1
o1-03 Digital Operator Display Selection 0
o1-04
Setting unit for frequency parame-
ters related to V/f characteristics
0
o1-05 LCD Brightness Adjustment 3
o2-01
Local/Remote Key Function Selec-
tion
1
o2-02 STOP Key Function Selection 1
o2-03 User Parameter Default Value 0
o2-04 MxC/kVA Selection
5
*2
o2-05
Frequency Reference Setting
Method Selection
0
No. Name Default
Set-
ting
o2-06
Operation Selection when Digital
Operator is Disconnected
0
o2-07
Cumulative Operation Time Set-
ting
0
o2-08
Cumulative Operation Time Selec-
tion
0
o2-09
Initialization Specification Selec-
tion
0
o2-10 Fan operation time setting 0
o2-12
Fault Trace/Fault History Clear
Function
0
o2-14 kWh User Monitor Initialization 0
o2-18
*7
Capacitor maintenance setting 0
o3-01 Copy Function Selection 0
o3-02 Copy Allowed Selection 0
T1-00 Motor Selection 1/2 1
T1-01 Auto-Tuning Mode Selection 0
T1-02 Motor Rated Power
5.50
*2
T1-03 Motor Rated Voltage
200.0
*3
T1-04 Motor Rated Current
19.60
*2
T1-05 Motor Base Frequency 60.0
T1-06 Number of Motor Poles 4
T1-07 Motor Base Speed 1750
T1-08 Number of PG Pulses 600
T1-09 Motor No-Load current 5.10
T1-10 Motor Rated Slip 1.50
No. Name Default
Set-
ting
Table 10.2 Parameters (Continued)
* 1. The default will change when the control method is changed. The Open Loop Vector defaults are given.
* 2. The defaults depend on the MxC capacity. The values for a 200 V class MxC of 5.5 kW are given.
* 3. These are values for a 200 V class MxC. Values for a 400 V class MxC are double.
* 4. E1-11 and E1-12 are disregarded when set to 0.0.
* 5. E1-13 is set to the same value as E1-05 by Auto-Tuning.
* 6. The defaults in the parentheses are for 3-wire sequence.
* 7. Applicable for the Varispeed AC with software versions PRG: 1050 or later.
* 8. Applicable for the Varispeed AC with software versions PRG: 1052 or later.