6-24
Setting Precautions
The motor may stall if the motor capacity is relatively small compared to capacity of the MxC, or if the
motor is operated with its defaults settings. Here, lower the value set to parameter L3-14.
If using the motor in the constant torque range, L3-14 will be automatically lowered to prevent stalling.
L3-03 is the limit value to prevent the stall prevention level in the constant torque range from being
reduced more than necessary.
Set L3-14 as a percent with the MxC rated voltage as 100%.
Fig 6.25 Stall Prevention Level and Limit during Deceleration
Stall prevention level during
deceleration
L3-02
(Stall Prevention Level during Deceleration)
L3-02 × L3-03
(Stall Prevention Limit during Deceleration)
Output frequency
E1-06
Base Frequency (FA)