Confirmations upon Delivery
1-5
MxC Model Numbers
The model number of the MxC on the nameplate indicates the specification, voltage class, and maximum
motor capacity of the MxC in alphanumeric code.
Fig 1.2 MxC Model Numbers
MxC Specifications
The MxC specifications (“SPEC”) on the nameplate indicate the voltage class, maximum motor capacity, the
protective structure, and the version of the MxC.
Fig 1.3 MxC Specifications
TERMS
Open Chassis Type (IEC IP00)
Protected so that no one can come in direct contact with electrically charged parts from the front when the
MxC is mounted in a control panel.
Enclosed Wall-Mounted Type [IEC IP20, NEMA 1 (Type 1)]
The MxC is structured so that the MxC is shielded from the exterior, and can thus be mounted to the interior
wall of a standard building (not necessarily enclosed in a control panel). The protective structure conforms to
the standards of NEMA 1 (Type 1) in the USA. The protective covers are required for an IEC IP20 or NEMA 1
(Type 1) protective structure.
CIMR - AC A 4 011
MxC
No.
A
Standard model
Specification
No.
2
4
AC input, 3-phase, 200 V
AC input, 3-phase, 400 V
Voltage Class
No.
5P5
011
022
5.5 kW
22 kW
045
45 kW
075
75 kW
11 kW
Max. Motor Capacity
"P" indicates the decimal point.
110
110 kW
160
160 kW
4 011 1 A
No.
0
1
Open chassis (IEC IP00)
Enclosed wall-mounted
[IEC IP20, NEMA 1 (Type 1)]
Protective Structure
No.
2
4
AC input, 3-phase, 200 V
AC input, 3-phase, 400 V
Voltage Class
No.
5P5
011
022
5.5 kW
22 kW
045
45 kW
075
75 kW
11 kW
Max. Motor Capacity
110
110 kW
160
160 kW
"P" indicates the decimal point.
No.
A to Z
Design revision order (A to Z)
Revision