3. PLC Monitoring Function
3.1 Overview
6-47
3. PLC Monitoring Function (PLC Timing Chart Function)
3.1 Overview
PLC monitoring function is used to check the state of mechanical I/O signals.
Ladder diagram shows a specific condition to bring a machine or an NC unit to a
certain state (alarm generation, feed hold, coolant delivery, magazine rotation, tool
clamping, etc.); however, it is usually impossible to know the mechanical I/O
signal at the moment that a condition is given. With this function, it is possible to
know it.
3.2 How to Start Monitoring Function
Select the ‘Diagnosis’ screen and ‘PLC’ in general diagnosis, and press the F8
(finger) key to show the ‘MONITOR’ menu. Press the menu to start the monitoring
function (Fig. 1).
Fig. 1 Time chart screen
Sampling Start ---- When the trigger condition is set, sampling starts.
DISP SLCT ---- Displays the trigger position in such a way to make the
position being 0/29/59 of the scale.
Changes the display position.
SETTING ---- The menus to perform various setups of the timing chart
appear in the case of the operation modes other than
“Ref. Point Return” and “Manual Operation.”
DISP SLCT ---- Selects reference cursor.
Selects three options of “None Selected,” “Ref 1,” and
“Ref 2.”
§ / ¨ ---- Moves to selected cursor position.
---- Displays other diagnosis menus.
MDI
Mode
DIAG
DATA NUM
TRIGGER
DISP POS
Start
Sampling
Start
SETT
ING
DISP
SLCT
Cursor
Selection