Page view 55
2-
Chapter 2 SERVO
0712
READY OFF ERROR
The V-READY is still off (diagnosis “0007 bit2=1”) even though the P-READY
(diagnosis “0007 PRD”) is on.
Turn on the reset key to release the alarm after eliminating the cause.
If the parameter “1815 VOC = 1,” the alarm is cancelled.
Items Cause of Trouble How to Verify Measures
1
AC 220V power
supply failure or
undervoltage to
the servo unit.
Make sure that the magnet contactor
and the relay for the servo unit are
ON, and then measure the voltages
between R, S, and T and between r
and t of the servo unit.
Eliminate a root
cause including
connection error,
etc.
2
Power supply
failure or
undervoltage to
the coils of the
magnet contactor
and relay for the
servo unit.
Make sure that the magnet contactor
and the relay for the servo unit are not
ON, and then check the coil voltage.
Eliminate a root
cause including
connection error,
etc.
3
Inferior magnet
contactor and
relay
Replace the
magnet contactor
and the relay
4
Problems on the
sequences
Check the sequences
Eliminate a root
cause.
5
The servo unit is
inferior.
Replace the servo
unit.
6
The EPS3 board
is inferior.
Replace the EPS3
board.