2. SENTROL2 PARAMETER
7-17
7 6 5 4 3 2 1 0
1601 OVB
-
OVB 1: The Block Overlap function is used.
0: The Block Overlap function is not used.
Linear type rapid traverse acceleration/deceleration time constant is established for
each axis according to this parameter.
Data range : 0~1000 Data unit : msec
speed
rate
1621 FL (RAPID)
Linear type rapid traverse accleration/deceleration FL rate is established for each axis
Axis type
Increment system
IS-A IS-B IS-C unit
Linear axis 10.0 1.0 0.1 mm/min
Rotary axis 10.0 1.0 0.1 deg/min
Data range : 0~32767
1622 TIME CONSTANT (FEED)
Cutting feed acceleration/deceleration(exponential type) time constant is established for each axis
Data range : 0~4000 Data unit : msec
SPEED (FEED, JOG, THREAD CUTTING)
ACC./DEC.
TIME
1620 TIME CONSTANT (RAPID)
FL SPEED
TIME
(rapid traverse)
FL rate
Rapid
traverse
Acc./dec.
Time constant
time
Comments to this Manuals