YASKAWA VS-626M5 Instruction Manual Page 50

  • Download
  • Add to my manuals
  • Print
  • Page
    / 268
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 49
Chapter 1 Troubleshooting and Treatment
1-36
7. Communication Troubles
Present state: In spite of trying to enter the program in edit mode from an external device, the
length of entered tape is not displayed while the message “being entered” is
flickering on the screen.
The operator tried to operate the DNC, but the number indicating the length of
entered tape remains as ‘0.00 m’ and does not change, while the message
“being entered” is flickering on the screen.
In spite of trying to output the program in edit mode from an external device, it
is impossible to input the program into the PC, while the message “being
output” and the length of the tape are displayed on the NC screen.
Items Cause of Trouble How to Verify Measures
1
Improper cable
wiring
Check the cable wiring.
2
Parameter setting
error
Make adjustment between the
communication device and the parameters
of the SENTROL2.
Refer to Appendix
14 of this manual
(pages 9-19).
3
No ‘%’ signal at
the head of the
program.
1) Is there the ‘%’ signal at the head of the
program?
2) Is the software one to whose head the ‘%’
signal is attached during communication,
even when the signal does not exist at
the head of the program?
Refer to Appendix
14 of this manual
(pages 9-18).
4
Telecommunicatio
n ICs in trouble
Check the connector voltage of the
SENTROL2 side
(25PIN connector
/9PIN connector) (Normal voltage)
SD (2PIN/3PIN)
- 8 ~ - 12V
SG (7PIN/5PIN)
RD (3PIN/2PIN)
0V ~ 0.5V
SG (7PIN/5PIN)
RS (4PIN/7PIN)
- 8 ~ - 12V
SG (7PIN/5PIN)
CS (5PIN/8PIN)
0V ~ 0.5V
SG (7PIN/5PIN)
Possibility of IC
trouble when the
voltage is not
normal.
(Needs to replace
the CPU card.)
Please contact us.
제1장장해추적 처리
Page view 49
1 2 ... 45 46 47 48 49 50 51 52 53 54 55 ... 267 268

Comments to this Manuals