Fourth Functions (Constants n120 to n179)
No. Register
No. for
Trans-
mission
Name Setting
Range
Setting Unit Factory
Setting
User
Setting
Ref.
Page
120 0178 Frequency Reference 9
(Note 6)
0 to 9999
r/min
1 r/min 180 r/min 140
121 0179 Frequency Reference 10
(Note 6)
0 to 9999
r/min
1 r/min 0 r/min 140
122 017A Frequency Reference 11
(Note 6)
0 to 9999
r/min
1 r/min 0 r/min 140
123 017B Frequency Reference 12
(Note 6)
0 to 9999
r/min
1 r/min 0 r/min 140
124 017C Frequency Reference 13
(Note 6)
0 to 9999
r/min
1 r/min 0 r/min 140
125 017D Frequency Reference 14
(Note 6)
0 to 9999
r/min
1 r/min 0 r/min 140
126 017E Frequency Reference 15
(Note 6)
0 to 9999
r/min
1 r/min 0 r/min 140
127 017F Frequency Reference 16
(Note 6)
0 to 9999
r/min
1 r/min 0 r/min 140
128 0180 PID Control Selection 0 to 8 1 0 179
129 0181 PID Feedback Gain 0.00 to
10.00 Hz
0.01 1.00 182
130 0182 Proportional Gain (P) 0.0 to 25.0 0.1 1.0 181
131 0183 Integral Time (I) 0.0 to
360.0 s
0.1 s 1.0 181
132 0184 Derivative Time (D) 0.00 to
2.50 s
0.01 s 0.00 181
133 0185 PID Offset Adjustment 100% to
100%
1% 0% 182
134 0186 Upper Limit of Integral
values
0% to
100%
1% 100% 181
135 0187 Primary Delay Time
Constant for PID Output
0.0 to 10.0 0.1 s 0.0 182
136 0188 Selection of PID Feed-
back Loss Detection
0 to 2 1 0 183
137 0189 PID Feedback Loss De-
tection Level
0% to
100%
1% 0% 183
138 018A PID Feedback Loss De-
tection Time
0.0 to 25.5 0.1 s 1.0 183
139 018B Energy-saving Control
Selection (V/f Control
Mode)
0, 1 1 0 174
140 018C Energy-saving Coeffi-
cient K2
0.0 to 6550 0.1 (Note 7) 174
141 018D Energy-saving Control
Voltage Lower Limit at
60 Hz
0% to
120%
1% 50% 175