2.7 Arc Welding Instruction
2-233
5. ANTSTK
When AC=Current output value is selected from the table in part 2 of this Explanation, the fol-
lowing tag can be added or omitted.
No Tag Explanation Note
10
ANTSTK Specifies the automatic sticking release function.
The automatic wire sticking release function in
which the wire sticking is released automatically.
It puts out a constant voltage without outputting
the wire sticking signal once wire sticking is
detected.
Refer to the supple-
ment “Automatic wire
sticking release func-
tion”.
Automatic wire sticking release function
The automatic wire sticking release function in which the wire sticking is released automat-
ically. It puts out a constant voltage without outputting the wire sticking signal once wire
sticking is detected. The condition of the frequency etc. of the wire sticking release pro-
cessing is set in the auxiliary condition file.
For details of the automatic wire sticking release function, refer to the “Operator’s Manual
for Arc Welding”.
SUPPLE-
MENT
Automatic sticking release
Even if a single attempt has failed, the process is repeated