6-36
Hunting-Prevention Function
The Hunting-Prevention Function suppresses hunting when the motor is operating with a light load. This func-
tion can be set in V/f Control.
Related Parameters
Parameter
Number
Name
Description
Setting
Range
Default
Change
during
Run
Control Methods
Display
V/f
Open
Loop
Vector
Flux
Vector
n1-01
Hunting Preven-
tion Selection
0: Hunting-prevention function disabled
1: Hunting-prevention function enabled
The hunting-prevention function suppresses
hunting when the motor is operating with a
light load.
This function is enabled in V/f Control
method only.
If high response is to be given priority over
vibration suppression, disable the hunting-
prevention function.
0 or 1 1 No A No No
Hunt Prev Select
n1-02
Hunting Preven-
tion Gain Setting
Set the hunting-prevention gain multiplication
factor.
Normally, there is no need to make this set-
ting.
Adjust this parameter as follows:
If vibration occurs with light load, increase
the setting.
If the motor stalls, reduce the setting.
If the setting is too large, the voltage will be
too suppressed and the motor may stall.
0.00 to
2.50
1.00 No A No No
Hunt Prev Gain
n1-03
Hunting Preven-
tion Time Constant
Set the hunting-prevention primary delay time
in units of ms.
0 to 500 10 ms No A No No
Hunt Prev Time