8-6
4. Unscrew the four screws on the fan cover, and remove the fan cover from the MxC.
5. Remove the external cooling fan and replace it with a new one.
6. Reverse the procedure to install the new external cooling fan.
External Cooling Fan Installation Precautions
When installing the new external cooling fan, note that the air intake for the external cooling fan’s ventila-
tion is on the top of the MxC.
When reconnecting the power lead for the external cooling fan, place it near to the hole for the lead wire on
the fan cover. This will prevent the wire from getting pinched.
After the power lead of the external cooling fan is passed through the hole on the fan cover, attach the rub-
ber bushing.
There shouldn’t be an problems if connectors CN26 and CN27 are accidentally reversed when reconnect-
ing components. This is because CN26 and CN27 have the same electrical specifications.
Mounting screws for fan cover
Fan cover
Air flow
Pull the power lead
for the fan from here.
BackFront
Mounting screws for
external cooling fan
Mounting screws for
external cooling fan
External cooling fan
Rubber bushing
Fan cover
Hole for lead wire