Machine Protection
6-39
Reduction Ratio of Carrier Frequency and Rated Current
The following table shows the reduction ratio of the carrier frequency and rated current.
Model: CIMR-ACA25P5, 2011, 2022, 2045, 45P5, 4011, 4045, and 4075
Model: CIMR-ACA4022
Models: CIMR-ACA4110 and 4160
Note: 100% means the rated output current value of the MxC.
Carrier Frequency
(kHz)
Continuous Rating 60-second Rating
4 100% 150%
8 90% 135%
12 80% 120%
Carrier Frequency
(kHz)
Continuous Rating 60-second Rating
4 100% 150%
8 80% 120%
12 60% 90%
Carrier Frequency
(kHz)
Continuous Rating 60-second Rating
4 100% 150%