Parameter Tables
5-35
* The defaults in the parentheses are for 3-wire sequence.
Multi-Function Contact Input Functions
H1-09
Multi-Function
Digital Input Ter-
minal S11 Func-
tion Selection
Multi-function contact input 9 0 to 78 7 No A A A 408H -
Terminal S11 Sel
H1-10
Multi-Function
Digital Input Ter-
minal S12 Func-
tion Selection
Multi-function contact input 10 0 to 78 15 No A A A 409H -
Terminal S12 Sel
Set
Value
Function
Control
Methods
Page
V/f
Open
Loop
Vector
Flux
Vector
0 3-wire sequence (Forward/Reverse Run Command) Yes Yes Yes 6-9
1 Local/Remote selection (ON: Operator, off: Parameter setting) Yes Yes Yes 6-67
2 Option/MxC selection (ON: Option card) Yes Yes Yes
6-74
6-141
3
Multi-step speed reference 1
When H3-09 (Multi-function analog input (terminal A2) function selection) is set to
0 (Auxiliary frequency reference), this function can be used with the master/auxiliary
speed switch.
Yes Ye s Ye s 6 -5
4 Multi-step speed reference 2 Yes Yes Yes 6-5
5 Multi-step speed reference 3 Yes Yes Yes 6-5
6 Jog Frequency Command (higher priority than multi-step speed reference) Yes Yes Yes 6-5
7 Accel/decel time 1 Yes Yes Yes 6-18
8 External baseblock NO (NO contact: Baseblock at on) Yes Yes Yes 6-68
9 External baseblock NC (NC contact: Baseblock at off) Yes Yes Yes 6-68
A Accel/decel ramp hold (ON: Accel/decel stopped, frequency on hold) Yes Yes Yes 6-69
B OH2 alarm signal input (ON: OH2 will be displayed) Yes Yes Yes -
C Multi-function analog input selection (ON: Enable) Yes Yes Yes -
E Speed control integral reset (ON: Integral control disabled) No No Yes 6-116
F Not used (Set when a terminal is not used) - - - -
10 Up Command (Always set with the Down Command) Yes Yes Yes 6-70
11 Down Command (Always set with the Up Command) Yes Yes Yes 6-70
12 FJOG Command (ON: Forward run at jog frequency d1-17) Yes Yes Yes 6-75
13 RJOG Command (ON: Reverse run at jog frequency d1-17) Yes Yes Yes 6-75
14 Fault reset (Reset when turned on) Yes Yes Yes 7-2
15
Emergency stop (Normally open condition: Decelerate to stop in deceleration time
set in C1-09 when on).
Yes Ye s Ye s 6- 16
16 Motor Switch Command (Motor 2 selection) Yes Yes Yes -
17
Emergency stop (Normally closed condition: Decelerate to stop in deceleration time
set in C1-09 when off)
Yes Ye s Ye s 6- 16
Parameter
Number
Name
Description
Setting
Range
Default
Change
during
Run
Control
Methods
MEMO-
BUS
Register
Page
Display
V/f
Open
Loop
Vector
Flux
Vector