Adjusting Frequency References
6-29
Setting Jump Frequency Reference Using an Analog Input
When parameter H3-09 (Terminal A2 Function Selection) or H3-05 (Terminal A3 Function Selection) is set to
A (jump frequency), the jump frequency can be changed using the terminal A2 input level.
Fig 6.32 Jump Frequency Setting Using an Analog Input
Setting Precautions
Set the jump frequency according to the following formula: d3-01 d3-02 d3-03 > Analog input.
When parameters d3-01 to d3-03 are set to 0 Hz, the jump frequency function is disabled.
Jump frequency
0 V
(4 mA)
Multi-function analog input
terminal A2 or A3 input level
10 V
(20 mA)
Max output frequency
E1
-