6-139
Related Parameters
Setting Output Items for the DO-02C Digital Output Card
If using DO-02C Digital Output Card, set the output items using F5-01 and F5-02.
Parameter
Number
Name
Description
Setting
Range
Default
Change
during
Run
Control Methods
Display
V/f
Open
Loop
Vector
Flux
Vector
F5-01
DO-02/DO-08
Channel 1 Output
Selection
Sets the digital output function number for
channel 1. See the H2 parameter group for
possible selections.
Enabled when digital output card DO-02 or
DO-08 is used.
0 to 37 0 No A A A
DO Ch1 Select
F5-02
DO-02/DO-08
Channel 2 Output
Selection
Sets the digital output function number for
channel 2. See the H2 parameter group for
possible selections.
Enabled when digital output card DO-02 or
DO-08 is used.
0 to 37 1 No A A A
DO Ch2 Select
F5-03
DO-08 Channel 3
Output Selection
Sets the digital output function number for
channel 3. See the H2 parameter group for
possible selections.
Enabled when digital output card DO-02 or
DO-08 is used.
0 to 37 2 No A A A
DO Ch3 Select
F5-04
DO-08 Channel 4
Output Selection
Sets the digital output function number for
channel 4. See the H2 parameter group for
possible selections.
Enabled when digital output card DO-02 or
DO-08 is used.
0 to 37 4 No A A A
DO Ch4 Select
F5-05
DO-08 Channel 5
Output Selection
Sets the digital output function number for
channel 5. See the H2 parameter group for
possible selections.
Enabled when digital output card DO-02 or
DO-08 is used.
0 to 37 6 No A A A
DO Ch5 Select
F5-06
DO-08 Channel 6
Output Selection
Sets the digital output function number for
channel 6. See the H2 parameter group for
possible selections.
Enabled when digital output card DO-02 or
DO-08 is used.
0 to 37 37 No A A A
DO Ch6 Select
F5-07
DO-08 Channel 7
Output Selection
Sets the digital output function number for
channel 7. See the H2 parameter group for
possible selections.
Enabled when digital output card DO-02 or
DO-08 is used.
0 to 37 0F No A A A
DO Ch7 Select
F5-08
DO-08 Channel 8
Output Selection
Sets the digital output function number for
channel 8. See the H2 parameter group for
possible selections.
Enabled when digital output card DO-02 or
DO-08 is used.
0 to 37 0F No A A A
DO Ch8 Select
F5-09
DO-08 Output
Mode Selection
Sets the function of the DO-08 digital output
option card.
0: 8-channel individual outputs.
1: Binary code output.
2: 8-channel Selected - Output according to
F5-01 to F5-08 settings.
0 to 2 0 No A A A
DO-08 Selection